| ARS-1
FULLY REINFORCED ELASTOMERIC MEMBRANE ROOFING SYSTEMS |
| USE |
SPEC
# |
DESCRIPTION |
Application Guides
|
| FULLY REINFORCED
SYSTEMS for ASPHALT ROOFS |
ARS-1A
|
The ARS-1A system
provides a reinforced elastomeric membrane with a minimum final
membrane thickness of 40 mils and an average membrane thickness
of 45 mils. For recovering smooth and granulated surface asphalt
substrates including existing BUR and Modified Bitumen roofs. |
|
|
|
|
ARS-1A(50XT)
|
The
ARS-1A(50XT) system provides a reinforced elastomeric membrane with
a minimum final membrane thickness of 45 mils and an average membrane
thickness of 50 mils. Acrymax AF-130XT high-strength elastomeric
coating is used as the finish coat for added durability. For recovering
smooth and granulated surface asphalt substrates including existing
BUR and Modified Bitumen roofs. |
|
|
|
| FULLY REINFORCED
SYSTEMS for CONCRETE ROOFS |
ARS-1C
|
The ARS-1C system
provides a reinforced elastomeric membrane system with a minimum
final membrane thickness of 40 mils and an average membrane thickness
of 45 mils. For weatherproofing concrete roofs. |
|
|
|
|
ARS-1C(50XT)
|
The ARS-1C(50XT)
system provides a reinforced elastomeric membrane with a minimum
final membrane thickness of 45 mils and an average membrane thickness
of 50 mils. Acrymax AF-130XT high-strength elastomeric coating is
used as the finish coat for added durability. For weatherproofing
concrete roofs. |
ARS-1C(50XT) Application
Guide
HTML
|
|
|
| FULLY REINFORCED
SYSTEMS for SINGLE-PLY ROOFS |
ARS-1SP
|
The ARS-1SP system
provides a reinforced elastomeric membrane with a minimum final
membrane thickness of 40 mils and an average membrane thickness
of 45 mils. Integrates the existing membrane into a new composite
membrane adding redundancy and additional benefits to the overall
system. For recovering single-ply membranes including EPDM, Hypalon,
and PVC. |
|
|
|
|
ARS-1SP(50XT)
|
The
ARS-1SP(50XT) system provides a reinforced elastomeric membrane
with a minimum final membrane thickness of 45 mils and an average
membrane thickness of 50 mils. Integrates the existing membrane
into a new composite membrane adding redundancy and additional benefits
to the overall system. Acrymax AF-130XT high-strength elastomeric
coating is used as the finish coat for added durability. For recovering
single-ply membranes including EPDM, Hypalon, and PVC. |
|
|
|
| FM
APPROVED SYSTEM |
ARS-1FR
|
FM Approved system
for weatherproofing smooth and granulated surface asphalt substrates
including existing BUR and Modified Bitumen roofs. The ARS-1FR system
provides a reinforced elastomeric membrane with a minimum final
membrane thickness of 40 mils and an average membrane thickness
of 45 mils. FM approved for use on existing asphalt roofs when applied
according to specification. |
|
|
|
| ARS-2
PARTIALLY REINFORCED ELASTOMERIC MEMBRANE ROOFING SYSTEMS |
| USE |
SPEC
# |
DESCRIPTION |
Application Guides
|
| ARS-2A PARTIALLY
REINFORCED SYSTEMS for ASPHALT ROOFS |
ARS-2 (A25)
|
The ARS-2(A25)
system provides a partially reinforced elastomeric membrane with
an average of 25 mils and a minimum 22 mils on the field of the
roof and an average of 45 mils and a minimum of 42 mils on the reinforced
areas. For protection, maintenance and weatherproofing of smooth
or granulated surface asphalt substrates including existing BUR
and modified bitumen roofs. |
|
|
|
|
ARS-2 (A30XT)
|
The
ARS-2(A30XT) system provides a partially reinforced system with
an average of 30 mils and a minimum of 27 mils on the field of the
roof and an average of 50 mils and a minimum of 47 mils on the reinforced
areas. Acrymax AF-130XT high-strength elastomeric coating is used
as the finish coat for added durability. For protection, maintenance
and weatherproofing of smooth or granulated surface asphalt substrates
including existing BUR and modified bitumen roofs. |
|
|
|
| ARS-2C PARTIALLY
REINFORCED SYSTEMS for CONCRETE ROOFS |
ARS-2 (C25)
|
The ARS-2(C25)
system provides a partially reinforced elastomeric membrane with
an average of 25 mils and a minimum 22 mils on the field of the
roof and an average 45 mils and a minimum of 42 mils on the reinforced
areas. For protection, maintenance and weatherproofing of concrete
roofs. |
|
|
|
|
ARS-2 (C30XT)
|
The ARS-2(C30XT)
system provides a partially reinforced elastomeric membrane with
an average of 30 mils and a minimum of 27 mils on the field of the
roof and an average of 50 mils and minimum of 47 mils on the reinforced
areas. Acrymax AF-130XT high-strength elastomeric coating is used
as the finish coat for added durability. For protection, maintenance
and weatherproofing of concrete roofs. |
|
|
|
| ARS-2M PARTIALLY
REINFORCED SYSTEMS for METAL ROOFS |
ARS-2 (M15)
|
The ARS-2(M15)
system provides a partially reinforced elastomeric membrane with
an average of 15 mils and a minimum 12 mils on the field of the
roof and an average 40 mils and a minimum of 37 mils on the reinforced
areas. For protection and weatherproofing of metal roofs. |
|
|
|
|
ARS-2 (M20)
|
The
ARS-2(M20) system provides a partially reinforced elastomeric membrane
with an average of 20 mils and a minimum 17 mils on the field of
the roof and an average 45 mils and a minimum of 42 mils on the
reinforced areas. For protection and weatherproofing of metal roofs.
|
|
|
|
|
ARS-2 (M25XT)
|
The
ARS-2(M25XT) system provides a partially reinforced elastomeric
membrane with an average of 25 mils and a minimum 22 mils on the
field of the roof and an average 50 mils and a minimum of 47 mils
on the reinforced areas. Acrymax AF-130XT high-strength elastomeric
coating is used as the finish coat for added durability. For protection
and weatherproofing of metal roofs. |
|
|
|
| ARS-2SP PARTIALLY
REINFORCED SYSTEMS for SINGLE-PLY ROOFS |
ARS-2 (SP20XT)
|
The ARS-2(SP20XT)
provides a partially reinforced elastomeric membrane with an average
of 20 mils and a minimum 17 mils on the field of the roof and an
average 45 mils and a minimum of 42 mils on the reinforced areas.
Acrymax AF-130XT high-strength elastomeric coating is used as the
finish coat for added durability. For protection, maintenance and
weatherproofing of existing single-ply membranes including EPDM,
Hypalon, and PVC. |
|
|
|
| ARS-2
(SP30XT) |
The ARS-2(SP30XT)
provides a partially reinforced membrane with an average of 30 mils
and a minimum 27 mils on the field of the roof and an average 50
mils and a minimum of 47 mils on the reinforced areas. Acrymax AF-130XT
high-strength elastomeric coating is used as the finish coat for
added durability. For protection, maintenance and weatherproofing
of existing single-ply membranes including EPDM, Hypalon, and PVC.
|
|
|
|
| ARS-3
PROTECTIVE - REFLECTIVE COATING SYSTEMS |
| USE |
SPEC
# |
DESCRIPTION |
Application Guides
|
ARS-3
PROTECTIVE, REFLECTIVE &
COLOR COATING SYSTEMS |
ARS-3 (15)
|
The ARS-3(15)
system provides an elastomeric coating with an average thickness
of 15 mils and a minimum of 12 mils. For a variety of substrates
to provide reflectivity or color to the roof surface. |
|
|
|
|
ARS-3 (20)
|
The
ARS-3(20) system provides an elastomeric coating with an average
thickness of 20 mils and a minimum of 17 mils. For a variety of
substrates to provide protection, reflectivity, or color to the
roof surface. |
|
|
|
|
ARS-3 (15MB)
|
The
ARS-3(15MB) system provides a protective elastomeric coating with
an average thickness of 15 mils and a minimum thickness of 12 mils.
For modified bitumen roofs to provide protection from UV degradation,