%@LANGUAGE="VBSCRIPT" CODEPAGE="1252"%>
|
![]() |
||||||||||||||
|
ARS-2C
PARTIALLY REINFORCED ELASTOMERIC MEMBRANE SYSTEMfor CONCRETE ROOFS
APPLICATION GUIDE
1. DESCRIPTION
The ARS-2C Systems include the following:
2. MATERIALS The materials
used in the ARS-2C Systems may include AF-130BC Basecoat, AF-130 Finish-coat,
3. APPLICATION EQUIPMENT
Acrymax AF-130 Coatings can be applied by brush, roller, or
spray. Airless spray is the most efficient method of application where
proper conditions and expertise exist. Suggested spray equipment should
be capable of 2500 – 3000 psi with output of 2 - 2.5 gallons per minute.
Tip size .027 to .041. Application by roller or brush may require additional
coats to achieve uniform membrane thickness, but material requirements
will generally remain the same. Rollers should be medium or long nap. 4. INSTALLATION Installation of the ARS-2C Systems are accomplished in six
(6) basic steps: (a) Preparation,
(a) Preparation Acrymax AF-130 coatings must have a
clean surface to adhere to. Proper surface preparation is the key to
successful applications. All dirt, debris, oils etc. must be removed
by the most effective method possible. High-pressure water (2000 psi
minimum) is the preferred method. Vacuuming, stiff brooming, and low-pressure
water washing can also be used. When high-pressure water washing is
used it should be done at a pressure suitable to remove embedded dirt
and contaminants without damaging the substrate that is being cleaned
and care must also be taken to make sure that water does not intrude
into the building. Cleaner such
as TSP (or biodegradable alternative) should be used as necessary. All
residues must be thoroughly rinsed off. A tape test should be used to determine
acceptability of cleaned surface for coating application. This is done
by applying masking tape to the surface to be coated, and then peeling
off the tape. If the adhesive side of the tape shows contaminants that
will interfere with the adhesion of the coatings, then further cleaning
or use of a primer may be necessary. (b) repair All necessary repairs must be done
according to good construction practices. Unsound areas including spalled
or pitted areas must be repaired and made flush with the surrounding
areas. If concrete is repaired it should be done using concrete that
is modified with admixtures containing acrylic resins. Any concrete
repairs must be allowed to cure before application of Acrymax coatings.
Acrymax AF-130BC should be used with Poly-1 polyester
reinforcement fabric in appropriate widths to repair and reinforce cracks
and otherl defective areas in the existing roof surface. Acrymax (c) Priming Concrete surfaces should be primed
with AF-100 prior to application of Acrymax membrane. Primer application
rates can vary depending on the porosity of the concrete. Application
rates generally should be 250 square feet per gallon. Porous surfaces
may require application at rate of 150 – 200 square feet per gallon.
Previously painted or coated surfaces usually do not require primer. (d) Application of Poly-1 Reinforcement with AF-130BC Basecoat
Before application of coatings verify
that the surface to be coated is cleaned and prepared properly. At any
time during application of the Acrymax system if roof surface becomes
contaminated with dirt, dust or other materials that will interfere
with adhesion of the coatings then cleaning measures must be taken to
restore the surface to a suitable condition. All required materials
must be applied and minimum dry film thickness achieved. Flashings, penetrations, transitions, and other detail areas
requiring reinforcement All flashings, penetrations, transitions,
and other detail areas requiring reinforcement should be completed with
Poly-1 and Acrymax AF-130BC in the following manner:
1.
Apply heavy coat of
AF-130BC to area to be covered.
2.
Embed appropriate width
Poly-1 polyester fabric into this wet coat of AF-130BC. Poly-1 Fabric is available in 4”, 6”,
12”, 18”, and 40” widths.
3.
Apply additional Acrymax
AF-130BC to completely saturate fabric. Total AF-130BC used to embed
and saturate Poly-1 should be 3 gallons per 100 square feet. Estimated Acrymax AF-130BC
per 100 linear feet required to apply Poly-1 Fabric Reinforcement on
seams or penetrations:
Note: The estimated material requirements are for materials that
are required to apply tack coat used to embed Poly-1 and to provide
first saturating coat of Acrymax. During application of liquid applied
elastomeric membrane the seams and detail areas that have been reinforced
with Poly-1 (e) Application of Elastomeric Membrane Apply Acrymax Elastomeric Membrane
using the appropriate AF-130 coatings in the color desired. Contrasting
colors should be used for each coat. White
is the suggested finish color for energy efficiency and reduced thermal
stress on the roof. Dust should be blown off of surfaces to be coated
with compressed air or blowers before application of coatings. ARS-2(C25)
1.
Basecoat
- Apply 1st coat of elastomeric coating using Acrymax AF-130BC
applied in a uniform manner at minimum
application rate of 1.5 gallons per 100 square feet. Allow to dry a minimum of 2 to 4 hours.
2.
Finish Coat - Apply 2nd coat of elastomeric coating using Acrymax AF-130
applied in a uniform manner at minimum
application rate of 1.5 gallons per 100 square feet. ARS-2(C30XT)
Notes: Each consecutive application of AF-130 coating
should be applied in a perpendicular direction to the previous coat.
During final application of the Acrymax
finish coats special attention should be given to coating flashings
and critical areas to build adequate membrane thickness. When applied
by roller it can be difficult to get a uniform finish coating thickness.
It can be best when applying by roller to apply additional coats to
achieve uniform film thickness. Material requirements will stay the
same. (f) Inspection Inspect entire roof area and touch-up deficient areas with
additional Acrymax AF-130 or AF-130XT as necessary to insure complete
and uniform coverage. Special attention should be given to critical
areas of roof, ie: details, roof penetrations, etc. 5. LIMITATIONS These are general guidelines for application
of the Acrymax ARS-2C Systems. The material requirements may vary depending
on the specific job requirements. If
unusual conditions exist, contact Acrymax Technical Service at 610-566-7470.
Acrymax Fluid Applied Elastomeric roofing systems must be applied to
structurally sound substrates. All surfaces must be clean and dry before
application of roofing. The suitability of Acrymax coatings or systems
for an intended use shall be solely up to the user. Drying time and
coverage are not guaranteed. Acrymax
roofing systems must not be applied over wet insulation or related materials.
Failure of the substrate does not constitute failure of the Acrymax
coating or system. Acrymax systems are designed for use on well drained
roofs, however, it is acceptable for use where poor drainage causes
temporary ponding. Acrymax Coatings should not be applied when rain
or freezing temperatures are expected before coating is dry. 6. WARRANTY Acrymax offers limited material warranties
for the ARS-2C Systems when all materials are used in strictaccordance with all of Acrymax’s written
requirements and recommendations and required dry film thicknesses are
achieved. Acrymax’s sole responsibility under this limited material
warranty is for defective material and Acrymax’s obligation shall not
exceed the purchase price of the Acrymax materials used or part thereof
proven to be defective. Submittal of required documentation is required
for warranty. Consult Acrymax for details.
This warranty gives specific legal rights and you may have other
legal rights that vary from state to state. No statement by anyone may
supersede this limited Notes:
1.
Acrymax coatings are
waterborne. Consequently application of these materials must not be
done when rain or other conditions such as fog or heavy dew are possible
before coating can dry sufficiently to be resistant to these occurrences.
Drying time is affected by numerous factors including temperature, direct
sunlight, relative humidity, air movement, thickness and color of applied
coating, etc... Under proper conditions dry times for coatings will
be from 2 to 4 hours, but under adverse conditions dry times can range
to 12 hours or more. Application
should not be done when temperatures are below 45oF or expected
to drop below freezing before coating is dry. Special attention should
be given to the dew point temperature because when this temperature
is reached and dew forms the drying process of the coatings will cease.
2.
Surfaces must always
be clean before application of AF-130 Coatings. Care must be taken to
insure that on-site manufacturing emissions or extended time intervals
after original cleaning do not interfere with any stage of the coating
applications. If either condition occurs then cleaning may
be required again.
3.
Adequate coating thickness
is essential to performance. If the applicator is unfamiliar in gauging
application rates, we suggest that a controllable area be measured and
the specified material be applied. In all cases all minimum specified
material must be applied and proper minimum dry film thicknesses must
be achieved. Care must be taken to insure that all areas completed including
all flashings, roof penetrations, etc. are coated sufficiently to insure
a watertight seal.
4.
Consult ACRYMAX TECHNOLOGIES
if any deviations from published specifications are considered. Unapproved
deviations from application guidelines and specified material requirements
may seriously affect the coating system performance, and shall be undertaken
at the specifier’s, applicator’s or building owner’s own risk.
5.
Applicator must comply
with all applicable local, state, and federal regulations if lead based
paint or other hazardous materials are encountered.
6.
Roofing is hazardous
work and coatings are very slippery when wet. Comply with fall protection
rules and regulations. Acrymax® is a registered trademark of Acrymax Technologies, Inc. 221 Brooke Street Media, PA 19063