The ARS-1 systems represent the latest in fluid applied composite roof membrane system technology. Combining Acrymax elastomeric roof coatings with high-strength reinforcement fabrics the ARS-1 Systems provide flexible and durable roof membranes that are used to cover a variety of substrates. The ARS-1 Systems provide a primary roof membrane that forms a continuous monolthic reinforced covering over the entire roof surface area. These roof membranes are fully adhered to the surface to which they are applied. Flashings and details use the same process to provide leak-free details that are completely integral to the roofing system.
The ARS-2 systems are a group of roofing systems where fabric reinforcement is used at critical roof areas and coatings alone are used on the roof areas that are not reinforced. These roof systems are used to produce elastomeric roof membranes with membrane thicknesses ranging from 15-30 mils on unreinforced areas and from 45-50 mils at reinforced areas. Number of coats and final thickness of the membrane are determined by the condition of the roof, the type of surface to be coated, and performance requirements of the roofing project.
These systems utilize roof coatings only. Acrymax ARS-3 Systems provide protective solutions for a range of applications. The ARS-3 Systems are used for energy saving reflectivity, to protect surfaces from UV degradation, and to provide architectural color to the roof.
Acrymax has developed systems specifically for use on historic structures. These materials are available exclusively from Preservation Products Inc., our affiliate company.
 |
Click on the links, below right, to download the corresponding
Installation Guide in Adobe PDF format.
To view an HTML version, choose the corresponding links on the left. |
ARS-1 Fully Reinforced Roof Membrane Systems |
Asphalt Roof Systems |
ARS-1-A |
Standard reinforced roof membrane system for asphalt roofs including BUR and Modified Bitumen. Membrane thickness - 45 mils. |
 |
ARS-1-A50XT |
Premium reinforced roof membrane system for asphalt roofs including BUR and Modified Bitumen. AF-130XT high-strength elastomeric finish. Membrane thickness - 50 mils. |
 |
ARS-1-FR |
FM Approved roof system for recovering asphalt roofs including BUR and Modified Bitumen. Membrane thickness - 45 mils. |
 |

|
|
|
Single-Ply Roof Systems |
ARS-1-SP
|
Standard reinforced roof membrane system for single-ply roofs including EPDM, Hypalon, PVC and other acceptable membranes. Membrane thickness - 45 mils. |
 |
ARS-1-SP50XT |
Premium reinforced roof membrane system for single-ply roofs including EPDM, Hypalon, PVC and other acceptable membranes. AF-130XT high-strength elastomeric finish. Membrane thickness - 50 mils. |
 |
|
|
|
Concrete Roof Systems |
ARS-1-C
|
Standard reinforced roof membrane system for concrete roofs. Membrane thickness - 45 mils. |
 |
ARS-1-C50XT |
Premium reinforced roof membrane system for concrete roofs. AF-130XT high-strength elastomeric finish. Membrane thickness - 50 mils. |
 |
|
|
|
Roof Board |
ARS-1-RB
|
Standard reinforced roof membrane system for DensDeck and other acceptable roof board. Membrane thickness - 45 mils. |
 |
ARS-1-RB50XT |
Premium reinforced roof membrane system for DensDeck and other acceptable roof board. AF-130XT high-strength elastomeric finish. Membrane thickness - 50 mils. |
 |

|
|
|
ARS-2 Partially Reinforced Roof Membrane Systems |
Metal Roof Systems |
ARS-2-M15 |
Partially reinforced elastomeric roof membrane system for metal roofs. Membrane thickness 15 mils on the field of the roof and 40 mils on the reinforced areas. |
 |
ARS-2-M20XT |
Standard partially reinforced elastomeric roof membrane system for metal roofs. Membrane thickness 20 mils on the field of the roof and 45 mils on the reinforced areas. |
 |
ARS-2-M25XT |
Premium partially reinforced elastomeric roof membrane system for metal roofs. AF-130XT high-strength elastomeric finish. Membrane thickness 25 mils on the field of the roof and 50 mils on the reinforced areas. |
 |
ARS-2-PVDF-A |
Partially reinforced elastomeric roof coating system for restoring metal roofs with existing factory applied fluoropolymer finishes. Uses Acrymax acrylic modified fluoropolymer coatings. Coating thickness 7-10 mils on the field of the roof and 40 mils on the reinforced areas. |
 |
ARS-2-PVDF-B |
Partially reinforced elastomeric roof coating system for metal roofs with high performance finish coat. Uses Acrymax acrylic modified fluoropolymer coatings as thin film finish over AF-130BC Elastomeric Acrylic Basecoat. Coating thickness 15 mils on the field of the roof and 45 mils on the reinforced areas. |
 |

|
|
|
Asphalt Roof Systems |
ARS-2-A25
|
Standard partially reinforced elastomeric roof membrane system for asphalt roofs. Membrane thickness 25 mils on the field of the roof and 50 mils on the reinforced areas. |
 |
ARS-2-A30XT |
Premium partially reinforced elastomeric roof membrane system for asphalt roofs. AF-130XT high-strength elastomeric finish. Membrane thickness 30 mils on the field of the roof and 55 mils on the reinforced areas. |
 |
|
|
|
Single-Ply Roof Systems |
ARS-2-SP20XT
|
Standard partially reinforced elastomeric roof membrane system for single-ply roofs. Membrane thickness 25 mils on the field of the roof and 50 mils on the reinforced areas. |
 |
ARS-2-SP30XT |
Premium partially reinforced elastomeric roof membrane system for single-ply roofs. AF-130XT high-strength elastomeric finish. Membrane thickness 30 mils on the field of the roof and 55 mils on the reinforced areas. |
 |
|
|
|
Concrete Roof Systems |
ARS-2-C25
|
Standard partially reinforced elastomeric roof membrane system for concrete roofs. Membrane thickness 25 mils on the field of the roof and 50 mils on the reinforced areas. |
 |
ARS-2-C30XT |
Premium partially reinforced elastomeric roof membrane system for concrete roofs. AF-130XT high-strength elastomeric finish. Membrane thickness 30 mils on the field of the roof and 55 mils on the reinforced areas. |
 |
|
|
|
ARS-3 Protective - Reflective Coating Systems |
Metal Roof Coating Systems |
ARS-3-M15 |
Protective and Reflective Roof Coating for Metal Roofs |
 |
ARS-3-PVDF-A |
Protective and architectural color coating system for metal roofs with existing factory applied fluoropolymer finishes. Uses Acrymax acrylic-modified PVDF coating for exceptional weatherability and color retention. |
 |
ARS-3-PVDF-B |
Protective and architectural color coating system for metal roofs. Uses Acrymax acrylic modified fluoropolymer coatings as thin film finish over AF-130BC Elastomeric Acrylic Basecoat. Modified PVDF finish coating provides exceptional weatherability and color retention. |
 |

|
|
|
Asphalt Roof Coating Systems |
ARS-3-A15MB
|
Protective and Reflective Roof Coating system for New Modified Bitumen Roofs |
 |
ARS-3-A20 |
Coating system to provide reflectivity, architectural color, and/or UV protection to asphalt roofs. |
 |
|
|
|
Single-Ply Roof Coating Systems |
ARS-3-SP15
|
Coating system to provide reflectivity or architectural color to single-ply roof membranes. |
 |
|
|
|
Concrete Roof Coating Systems |
ARS-3-C20
|
Coating system to provide reflectivity or architectural color to concrete roofs. |
 |
|
|
|
Roof Systems for Historic Roofs |
HP-1 |
Fully reinforced roof membrane system for weatherproofing existing terne metal or “tin” roofs and other historic structures. |
 |
HP-2 |
Partially reinforced roof membrane system for weatherproofing existing terne metal or “tin” roofs and other historic structures. |
 |
HP-3 |
Protective coating system for terne metal or “tin” roofs and other historic structures. |
 |

|
|
|